SEW 590/630 Series
The SEW 590/630 Series of Shakers are matched with the DSA 320K Series of Power Amplifiers. Its armature supply is assembled in three 19-inch network racks of 36 unit height and field supply is assembled in two 19-inch network racks of 36 unit height. The water cooling system is assembled in two 19-inch network racks of 36 unit height. All three system communicate with each other over a galvanically isolated RS 485 interface.
Standard Features
- Complies with Machinery Directives, Low Voltage Directive and Electromagnetic Compatibility Directive under CE
- Aluminium or Magnesium alloy armature structure
- Hydrostatic central guidance bearing
- Trunnion mounted shaker for operation in vertical and horizontal position
- Pneumatic and DC based auto-centring of armature head
- Body isolation using air bellows to isolate vibrations from the shaker
- Air isolation mounts between system base and ground
- Lowering of gauss level at the armature head
- Hermetically sealed construction
Optional Features
- Up to 76 mm (3.0 in) with Long Stroke
- PC based Power Amplifier Remote
- Auto Resume from power failure
- Auto Stop after user profile completion
- Attachment to Horizontal Slip Table and Head Expander
- Integration with Environmental Chamber
Technical Specifications
SEW 590/630 Series Shaker, DSA Series Amplifier | SEW 590/630 | |
System Performance | ||
Armature Diameter | 590 mm / 630 mm | |
Sine Force (peak) | 20000 kgf | |
Random Force (rms) | 20000 kgf | |
Shock Force (rms) | 40000 kgf | |
Acceleration (sine) | 100 g | |
Velocity (sine peak) | 1.8 m/s | |
Displacement (pk-pk) | 51 mm (2 in) / 76 mm (3 in) | |
Axial Resonance (±5%) | 1600 Hz | |
Useful Frequency Range | 5 to 2000 Hz | |
Protection Interlocks | Mains Input Over & Under Voltage, Over Current, Loss of Input Phase, Over Temperature Amplifier & Shaker, Field Fail, Cooling, User Safety Interlock if specifically required by the customer | |
Shaker Characteristics | ||
Moving Element Mass (±5%) | 150 kg | |
Internal Load Capability | 2000 kg | |
Suspension Axial Stiffness | 10 kg/mm | |
Suspension Cross-Axial Stiffness | 3200 kg/mm | |
Stray Magnetic Field* | < 0.5 mT (5 gauss) | |
Compressed Air** | 8 bar (115 psi) | |
Cooling | A dedicated cooling system for storing, circulating and cooling distilled water used for cooling | |
Amplifier Characteristics | ||
Power Output | 320 kVA | |
Total Harmonic Distortion*** | Typically 1% | |
Input Impedance | > 10 kΩ | |
Input Sensitivity | 4 Vrms, Compatible with all standard controllers | |
Signal-to-Noise Ratio | > 75 dB | |
Power Efficiency**** | > 92% |
Safety Norms | |
CE | Complies with Machinery Directive (2006/42/EC), Low Voltage Directive (2014/35/EU), and Electromagnetic Compatibility Directive (2014/30/EU) |
Notes: |
|
No Comments